16 research outputs found

    Modelling and testing the x-ray performance of CCD and CMOS APS detectors using numerical finite element simulations

    Get PDF
    Pixellated monolithic silicon detectors operated in a photon-counting regime are useful in spectroscopic imaging applications. Since a high energy incident photon may produce many excess free carriers upon absorption, both energy and spatial information can be recovered by resolving each interaction event. The performance of these devices in terms of both the energy and spatial resolution is in large part determined by the amount of diffusion which occurs during the collection of the charge cloud by the pixels. Past efforts to predict the X-ray performance of imaging sensors have used either analytical solutions to the diffusion equation or simplified monte carlo electron transport models. These methods are computationally attractive and highly useful but may be complemented using more physically detailed models based on TCAD simulations of the devices. Here we present initial results from a model which employs a full transient numerical solution of the classical semiconductor equations to model charge collection in device pixels under stimulation from initially Gaussian photogenerated charge clouds, using commercial TCAD software. Realistic device geometries and doping are included. By mapping the pixel response to different initial interaction positions and charge cloud sizes, the charge splitting behaviour of the model sensor under various illuminations and operating conditions is investigated. Experimental validation of the model is presented from an e2v CCD30-11 device under varying substrate bias, illuminated using an Fe-55 source

    Models for dynamic correlated charge collection effects in thick CCDs

    Get PDF
    Dynamic charge collection effects in thick CCDs have received interest in recent years, due to the performance implications for both ground and space based precision optical astronomy. The phenomena manifest as the "brighter - fatter" effect in Point Spread Function (PSF) measurements, and nonlinearity and signal dependence in spatial autocorrelation and photon transfer measurements. In this paper we present validation results from simple, analytically based predictive models for this effect, using an e2v CCD250. The model is intended to provide estimations for predicting device performance based on design parameters

    Development of the X-ray camera for the OGRE sub-orbital rocket

    Get PDF
    Current theories regarding the matter composition of the universe suggest that half of the expected baryonic matter is missing. One region this could be residing in is intergalactic filaments which absorb strongly in the X-ray regime. Present space based technology is limited when it comes to imaging at these wavelengths and so new techniques are required. The Off-Plane Grating Rocket Experiment (OGRE) aims to produce the highest resolution spectrum of the binary star system Capella, a well-known X-ray source, in the soft X-ray range (0.2keV to 2keV). This will be achieved using a specialised payload combining three low technology readiness level components placed on-board a sub-orbital rocket. These three components consist of an array of large format off-plane X-ray diffraction gratings, a Wolter Type 1 mirror made using single crystal silicon, and the use of EM-CCDs to capture soft X-rays. Each of these components have been previously reviewed with OGRE being the first project to utilise them in a space observation mission. This paper focuses on the EM-CCDs (CCD207-40 by e2v) that will be used and their optimisation with a camera purposely designed for OGRE. Electron Multiplying gain curves were produced for the back-illuminated devices at -80 degrees Celsius. Further tests which will need to be carried out are discussed and the impact of the OGRE mission on future projects mentioned

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700

    Models for dynamic correlated charge collection effects in thick CCDs

    Get PDF
    Dynamic charge collection effects in thick CCDs have received interest in recent years, due to the performance implications for both ground and space based precision optical astronomy. The phenomena manifest as the "brighter - fatter" effect in Point Spread Function (PSF) measurements, and nonlinearity and signal dependence in spatial autocorrelation and photon transfer measurements. In this paper we present validation results from simple, analytically based predictive models for this effect, using an e2v CCD250. The model is intended to provide estimations for predicting device performance based on design parameters
    corecore